Automatic fire water cannon system(Low Flow)
The de degree of protection of ZDMS0.6/10S-LZIIIand ZDMS0.6/5S-LZIII automatic fire water monitors is IP53 (rain proof, 60º direction water spraying and dust prevention). The water cannon body rotates and the upper end cover is fixed so that the connecting cable on the water cannon terminal will not be loose or entangled with the cannon body. The water monitor has built-in electric control valve, so there is no need to configure solenoid valve on the system pipe network again. Due to the built-in filter of the water monitor, the water monitor is more adaptable to the water quality.
The water cannon has built-in indicator lights of three colors. When the water cannon is under monitoring status, the indicator light is green and flashes, indicating that the communication is normal. When the UV flame detector sends out the warning signal, the indicator light turns from green flashing to blue flashing.
When the thermal imaging detector of the water monitor confirms that a fire has occurred, the indicator light will flicker green and change to red, and the sounder with flashing light alarm of the field operation panel and the water monitor controller will be activated at the same time.
When the automatic fire water monitor receives the fire alarm (UV or IR) signal, the water monitor built-in image IR flame detector will automatically rotate along with the water monitor and lock the flame for 3 seconds, then spray to extinguish the fire. Otherwise, the water monitor will be considered as a false alarm, and the water monitor will reset automatically.
The water cannon built-in image IR flame detector locks the fire source under the condition that any of the conditions of difference temperature and constant temperature reach the set threshold.
Fire alarm detection radius of built-in UV flame detector: when the installation height of water monitor is 10m, the detection radius is 35 ~ 40m and the field of view angle (FOV) is 120°. The detection and alarm radius of the detector decreases with the decrease of the installation height.
Fire alarm detection radius of built-in IR image flame detector: coordinate axis X is 15°, coordinate axis Y is 55°, and the detection distance is 80m.
Before the factory delivery product, according to the installation height requirements of the water monitor provided by the user, the parameters such as the pitch angle compensation value of the water monitor corresponding to the installation height of the water monitor can be set in the program of the water monitor, so that the water monitor can accurately lock the flame center and spray fire extinguishing.
The working process of water monitor is two stages:
1. Stage I: after the fire alarm is found by the built-in or external flame detector of the water monitor, the water monitor will rotate automatically according to the set automatic rotation angle range. The built-in infrared image flame detector locks the static or moving fire source center and carries out fixed-point spraying, so as to quickly suppress the fire source. The fixed-point injection time is 3 seconds.
2. The second stage: the swinging water spraying program is started after the water monitor sprays water at a fixed point for 3S. The swinging water spraying time of the water monitor is 155 seconds.
The set time of each detection on water monitor to the completion of water spraying is 180 seconds. The water spraying process of water monitor is two processes: fixed-point water spraying and swing water spraying. The swinging water spraying procedure shall be started after the water monitor sprays water at a fixed point for 5S. The swinging angle of the water monitor is 6° up, 6° down, 3° left and 3° right. The swinging water spraying time of the water monitor is 155s.
1. ZDMS0.6/10S-LZIII and ZDMS0.6/5S - LZIII Automatic Fire Water monitor
The installation height is 6-15m, the maximum protection radius is 35m (or 30m), Monitoring radius is 40m. the rated working pressure is 0.6~0.8Mpa, and the rated working flow is 10L / S (or 5.0L / S). Built-in Infrared thermal imaging flame detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector.. The interface flange DN50. The cable outlet length of video, communication and power integration is 1.5m. The one minute wiring design is simple and easy to use. Without debugging, it can be put into use after installation.
Model |
ZDMS0.6/10S-LZII |
ZDMS0.6/5.0S- LZIII |
Rated Flow |
10L/S |
5.0L/S |
Rated Working Pressure |
0.6Mpa |
Maximum Working Pressure |
1.0Mpa |
Mounting Height |
6~15M |
Maximum Protection Radius |
35M |
30M |
Jet-flow radius |
39M |
34M |
Monitoring radius |
40M |
40M |
Nominal diameter |
DN50mm |
Degree of protection |
IP53 |
Working Voltage |
100~242V AC |
Power Consumption |
Ready mode:10W |
Action mode:100W |
MODBUS RTU |
CAN |
Positioning Time |
≤30S |
Fire extinguishing time |
≤3 mins |
Environment temperature |
-10ºC~55ºC |
Horizontal Rotation Angle |
360° |
Vertical Rotation Angle |
-90°~ +30° |
Overall Dimensions (L×W×H) |
360mm×230mm×300mm Weight:8.5kg |
Component introduction
Field operation panel
The fire water monitor can select manual or automatic control and mist jet or columnar jet selection key through the local control panel button. At the same time, it supports field control, remote control, remote linkage control of control cabinet, synchronous indication of power supply status, system communication status, solenoid valve control status and alarm status. Built in fire alarm, built-in encoder, built-in alarm signal can be connected to the alarm host. English panel
Field operation panel parameters
Function |
Parameter |
Manual, AUTO: Manual / Automatic switching. |
Select spraying direction in manual mode: up, down, left and right. |
Model: CZP-1 |
Working voltage:AC110V~AC242V. |
Solenoid valve status:ON/OFF |
Column,FOG: Water monitor jet mode, columnar and foggy. |
Rated power:6W. |
Way to install:Wall mounted. |
Fire pump start and stop buttons:Fire pump ON, OFF. |
Alarm signal input and output. |
Ingress Protection: IP67 |
Indicator: Automatic, manual, fire alarm, valve, fire pump, fault, communication. |
Communication mode: CAN. |
One field operation panel controls one water monitor / one field operation panel controls multiple water monitor s (the number of waters monitor s cannot exceed 8pcs). |
Dimensions:( L ) 276×( W ) 190×( H )90(mm). Weight: 1.2kg. |
2. System Diagram of 10L/S, 5L/S Intelligent Fire Water monitor
Electrical wiring Diagram of 10L/S, 5/S Intelligent Fire Water monitor
Composition diagram of automatic fire water monitor system