FM, UL Certificated Linear Heat Detectors

Kunming Gen Qian Commercial Co., Ltd.
  • Audited Supplier
  • 12 yrs

Contact Supplier

Product Highlights

  • FM and UL Certified: Certified by FM, UL, CE, LVD, GOST-R, EAC, and CCCF for global compliance.
  • Early Alarm Detection: Provides very-early alarm detection with continuous sensitivity unaffected by environment.
  • Multiple Application Types: Available in Conventional, CR/OD (outdoor/weather resistant), and EP (explosion-proof) types.
  • Flexible Voltage Operation: Works with DC24V supply or without DC24V supply for versatile integration.
  • High IP Rating: IP66 rated for long-term use in high humidity (90%-98%) and harsh environments.
  • Precise Positioning: MS1000-L model offers positioning accuracy of 10m or within 5% of full length.
  • EMI and Static Resistance: EP type features woven metal mesh for anti-EMI and static elimination in hazardous areas.

Product Images of FM, UL Certificated Linear Heat Detectors

FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors pictures & photos
FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors
  • FM, UL Certificated Linear Heat Detectors
    FM, UL Certificated Linear Heat Detectors

Find Similar Products

Product Description

FM Proved Digital Type Linear Heat Detectors

1.  Application scope
Compared with other kinds of detectors. MS1000 digital linear heat detector provides a very-early alarm detecting function to the protected environment. The detector can be known as an intelligent "switch" type detector. The polymers between the two conductors will break down at specific fixed temperature allowing the conductors contact, the shot circuit will initiate the alarm. The detectors has a continuous sensitivity. The sensitivity of linear heat detector will not be influenced by the environment temperature changing and the length of detection cable using. It does not need to be adjusted and compensation. The detector can transfer both alarm and fault signals to control panels normally with DC24V or without DC24V. 
  
2. Classification 
Conventional type This type of Linear heat detection cable is the most widely indoor used with strong stability
CR/OD Type CR/OD type not only has good UV resistance and good weather resistance, strongly recommended for outdoor using even under bad weather conditions, but also with high performance of acid resistant, alkali-resistant, salt spray resistant.
EP Type Explosion proof type. Two main application environments: harsh EMI environment and explosive hazardous environment. The outer jacket of this type is protected by woven metal mesh with good performance of anti-EMI and eliminating the surface static of the linear heat detection cable. We can use this type linear heat detection cable in explosive hazardous environment with safety fence. During the installation, please make grounding connection of the woven metal mesh. Used in harsh EMI environment, single end grounding connection or double ends grounding connection should be specified after analysis of the interference sources.

3. Features and benefits
Industrial safety design.
Electrical interface with low power consumption design.
Real-time monitoring.
Working with DC24V supply or without DC24V supply.
Fast response time.
No alarm temperature compersation needed.
Compatible to any kind fire alarm system.
Plenty levels of alarm temperatures: from 60ºC to 180ºC

4. Technical parameter
1 Operating Voltage: DC24V
2 Allowed Voltage Range: DC 16V-DC 28V
3 Standby Current: ≤20 mA
4 Alarm Current:  ≤30 mA
5 Fault Current:  ≤25 mA
6 Maximum relative humidity for long term use: 90%-98%
7 IP degree: IP 66
8 Alarm temperatures range: 68ºC, 88ºC, 105ºC, 138ºC, 180ºC


Control Unit and EOL Box

MS1000-I Control Unit
Control unit MS1000-I is used for MS1000, MS1000-CR-OD and MS1000-EP digital type linear heat detection cable. MS1000 is a digital type linear heat detection cable with comparatively simple output signal, the control unit and EOL box are easy to install and operate. 

Techical parameters
Operating voltage: 24VDC
Allowed voltage range: 16VDC-28VDC
Operateing current: Standby current: ≤ 20mA
                                       Fire current: ≤ 30mA
                                     Fault current: ≤ 25mA
Operating environment:
temperature: -45ºC- +60ºC
Relative humidity: 95%
IP rating: IP66
Dimensions: 90mm×85mm×52mm (L×W×H)

MS1000-P terminal Unit (EOL box)
EOL Box for MS1000, MS1000-CR/OD and MS1000-EP digital linear heat detection cable. 
Techical parameters
Operating voltage: No electronics

Operating environment:
temperature: -45ºC- +60ºC
Relative humidity: 95%
IP rating: IP66
Dimensions: 90mm×85mm×52mm (L×W×H)
 

MS1000-L Control Unit and Locator
Control unit MS1000-L is a controlling device to monitor the temperature change of sensor cable and connected to mainframe of intelligent fire alarming control panel.

MS1000-L performs continuous monitoring over fire alarm and open circuit of monitored area as well as distance from fire alarm position. These alarming signals are shown on the LCD and indicators of MS1000-L.

Since fire alarm has locking function, MS1000-L must be disconnected to power and reset after ALARM. While fault function could automatically reset, it means that after the clearing fault, the fault signal of MS1000-L is automatically cleared. 

Features
Plastic shell: chemical resistance, aging resistance and impact resistance.
IP rating: IP66
With LCD, various alarming information could be shown
The detector has high ability of interruption resistance adopting fine grounding measurement, isolation test and software interruption resistance technique. It is able to apply in places with high electromagnetic field interruption. 

Techical parameters
Detector type: Linear heat detector MS1000
Operating voltage: DC 24V
Allowed voltage range: DC 16V-DC 28V
Operateing current: Standby current: ≤ 60mA
                                     alarm current: ≤ 80mA
 Alarming reset: disconnection reset
Operating environment:
temperature: -10ºC- +50ºC
Relative humidity: ≤95%, no condensation
Positioning accuracy: 10m or no longer than 5% of full length (under 25 ºC environment)
Application length: no longer than 1,000 meters
Outer shell protection class: IP66
FM, UL Certificated Linear Heat Detectors



FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors


FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors
FM, UL Certificated Linear Heat Detectors

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2291360". Items marked "verified" are certified.

Watch Video
Watch Video
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.
Kunming Gen Qian Commercial Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 1905#, Building 8, Tianyifengjing Residencial Quarter, Kunming, Yunnan, China
verified Plant Area
161 square meters
verified Number of Employees
3
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Automatic fire water monitor system, Linear Heat Detector, Automatic fire alarm system, Smoke detector and heat detector tester, Flame detector, Fire sticker
verified R&D Engineers
2 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2012-06-14
Export Year
2012-11-01
verified Main Markets
South America, Europe, Southeast Asia/ Mideast
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
UL

FAQ

What certifications does the linear heat detector have?
The detector is FM and UL certified. It also holds CE, LVD, GOST-R, EAC, and CCCF certifications.
What are the different types of linear heat detection cables available?
There are three types: Conventional (indoor use), CR/OD (outdoor, UV/weather/acid resistant), and EP (explosion-proof with EMI resistance).
Is the detector suitable for outdoor or hazardous environments?
Yes. The CR/OD type is recommended for outdoor use with bad weather. The EP type is designed for explosive hazardous and harsh EMI environments.
Does the detector require temperature compensation?
No, the detector has continuous sensitivity and does not need alarm temperature compensation or adjustment.
What is the maximum application length for the detector cable?
The application length is no longer than 1,000 meters for the MS1000-L model.
How does the MS1000-L control unit handle alarms and faults?
Alarms have a locking function requiring power disconnection and reset. Faults automatically reset after the fault is cleared.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now