Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)

Certification: CE, Cccf, CNAS, ILAC-MRA
Transport Package: Standard Export Packing
Specification: DN50 (2")
Trademark: GQ
Origin: China
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
ZDMS0.6/10S-LZII/ ZDMS0.6/5.0S- LZII
Production Capacity
10000

Product Description


Automatic fire water cannon system(Low Flow)
When the automatic fire water monitor receives the fire alarm (UV or IR) signal, the water monitor built-in image IR flame detector will automatically rotate along with the water monitor and lock the flame for 3 seconds, then spray to extinguish the fire. Otherwise, the water monitor will be considered as a false alarm, and the water monitor will reset automatically.
The water cannon built-in image IR flame detector locks the fire source under the condition that any of the conditions of difference temperature and constant temperature reach the set threshold.
Fire alarm detection radius of built-in UV flame detector: when the installation height of water monitor is 10m, the detection radius is 35 ~ 40m and the field of view angle (FOV) is 120 °. The detection and alarm radius of the detector decreases with the decrease of the installation height.
Fire alarm detection radius of built-in IR image flame detector: coordinate axis X is 15 °, coordinate axis Y is 55 °, and the detection distance is 80m.
Before the factory delivery product, according to the installation height requirements of the water monitor provided by the user, the parameters such as the pitch angle compensation value of the water monitor corresponding to the installation height of the water monitor can be set in the program of the water monitor, so that the water monitor can accurately lock the flame center and spray fire extinguishing.
The working process of water monitor is two stages:
1.    Stage I: after the fire alarm is found by the built-in or external flame detector of the water monitor, the water monitor will rotate automatically according to the set automatic rotation angle range. The built-in infrared image flame detector locks the static or moving fire source center and carries out fixed-point spraying, so as to quickly suppress the fire source. The fixed-point injection time is 3 seconds.
2.    The second stage: the swinging water spraying program is started after the water monitor sprays water at a fixed point for 3S. The swinging water spraying time of the water monitor is 155 seconds.
The set time of each detection on water monitor to the completion of water spraying is 180 seconds. The water spraying process of water monitor is two processes: fixed-point water spraying and swing water spraying. The swinging water spraying procedure shall be started after the water monitor sprays water at a fixed point for 5S. The swinging angle of the water monitor is 6 ° up, 6 ° down, 3 ° left and 3 ° right. The swinging water spraying time of the water monitor is 155s.
  1.  ZDMS0.6/10S-LZII,ZDMS0.6/5.0S- LZII  Automatic Fire Water monitorThe installation height is 6-15m, the maximum protection radius is 35m (or 30m), Monitoring radius is 40m. the rated working pressure is 0.6~0.8Mpa, and the rated working flow is 10L / S (or 5.0L / S). Built-in Infrared thermal imaging flame detector, UV flame detector, closed circuit television camera. Real time dynamic flame location and laser corrector.. The interface flange DN50. The cable outlet length of video, communication and power integration is 1.5m. The one minute wiring design is simple and easy to use. Without debugging, it can be put into use after installation.
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Model ZDMS0.6/10S-LZII ZDMS0.6/5.0S- LZII
Rated Flow 10L/S 5.0L/S
Rated Working Pressure 0.6Mpa
Maximum Working Pressure 1.0Mpa
Mounting Height 6~15M
Maximum Protection Radius 35M 30M
Nominal diameter DN50mm
Working Voltage 100~242V AC
Power Consumption Ready mode:10W Action mode:100W
MODBUS RTU CAN
Positioning Time 30S
Fire extinguishing time 3 mins
Environment temperature -10ºC~55ºC
Horizontal Rotation Angle 360°
Vertical Rotation Angle -90°~ +30°
Overall Dimensions (L×W×H) 360mm×230mm×300mm     Weight:8.1kg
Component introduction
Field control panel
The fire water monitor can select manual or automatic control and mist jet or columnar jet selection key through the local control panel button. At the same time, it supports field control, remote control, remote linkage control of control cabinet, synchronous indication of power supply status, system communication status, solenoid valve control status and alarm status. Built in fire alarm, built-in encoder, built-in alarm signal can be connected to the alarm host. English panel
 Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)                                               
Field control panel parameters
Function Parameter
Manual, AUTO: Manual / Automatic switching. Select spraying direction in manual mode: up, down, left and right. Model: CZP-1 Working voltage:AC110V~AC242V.
Solenoid valve status:ON/OFF Column,FOG: Water monitor jet mode, columnar and foggy. Rated power:6W. Way to install:Wall mounted.
Fire pump start and stop buttons:Fire pump ON, OFF. Alarm signal input and output. Ingress Protection: IP67
Indicator: Automatic, manual, fire alarm, valve, fire pump, fault, communication. Communication mode: CAN.
One local control panel controls one water monitor / one local control panel controls multiple water monitor s (the number of waters monitor s cannot exceed 32pcs). Dimensions:( L ) 276×( W ) 190×( H )90(mm).
Weight: 1.2kg.

Electrical control panel
The power supply of the electrical control panel is completed through the field control panel.
Each automatic fire water monitor is equipped with an electric control panel to provide power supply and all external wiring terminals for the water monitor and solenoid valve (electric valve and external UV flame detector), and quickly connect the water monitor through its own cable.
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Working Voltage 100~242V AC Ingress Protection IP67
Operating current Ready mode:100mA, Action mode:1A Operating temperature 4ºC~55ºC
MODBUS RTU CAN Dimensions: 276( L )×190( W )×90( H )(mm).  Weight: 1.0kg.
Switching value signal input, output, electric valve, pressure switch, water flow indicator and signal valve feedback signal input port.
DC24V power output port (external UV flame detector).
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)
Electrical wiring Diagram of 10L/S, 5/S Intelligent Fire Water monitor
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)Composition diagram of automatic fire water monitor system
Automatic Fire Water Monitor System (Low Flow: 5L/S, 10L/S)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Management System Certification
ISO 9001
Terms of Payment
LC, T/T